X74_174
6-Bit Data Register with Active-Low Asynchronous Clear
XC3000
| XC4000E
| XC4000X
| XC5200
| XC9000
| Spartan
| SpartanXL
| Virtex
|
Macro
| Macro
| Macro
| Macro
| Macro
| Macro
| Macro
| N/A
|
The active-Low asynchronous clear input (CLR), when Low, overrides the clock and resets the six data outputs (Q6 - Q1) Low. When CLR is High, the data on the six data inputs (D6 - D1) is transferred to the corresponding data outputs on the Low-to-High clock (CK) transition.
Inputs
| Outputs
|
CLR
| D6 - D1
| CK
| Q6 - Q1
|
0
| X
| X
| 0
|
1
| D6 - D1
|
| d6 - d1
|
dn = state of referenced input one setup time prior to active clock transition
|