XC3000 | XC4000E | XC4000X | XC5200 | XC9000 | Spartan | SpartanXL | Virtex |
---|---|---|---|---|---|---|---|
N/A | N/A | N/A | N/A | Macro | N/A | N/A | N/A |
CB2X1, CB4X1, CB8X1, and CB16X1 are, respectively, 2-, 4-, 8-, and 16-bit (stage), synchronously loadable, asynchronously clearable, bidirectional binary counters. These counters have separate count-enable inputs and synchronous terminal-count outputs for up and down directions to support high-speed cascading in the CPLD architecture.
The asynchronous clear (CLR) is the highest priority input. When CLR is High, all other inputs are ignored; data outputs (Q) go to logic level zero, terminal count outputs TCU and TCD go to zero and one, respectively, clock enable outputs CEOU and CEOD go to Low and High, respectively, independent of clock transitions. The data on the D inputs loads into the counter on the Low-to-High clock (C) transition when the load enable input (L) is High, independent of the CE inputs.
The Q outputs increment when CEU is High, provided CLR and L are Low, during the Low-to-High clock transition. The Q outputs decrement when CED is High, provided CLR and L are Low. The counter ignores clock transitions when CEU and CED are Low. Both CEU and CED should not be High during the same clock transition; the CEOU and CEOD outputs might not function properly for cascading when CEU and CED are both High.
For counting up, the CEOU output is High when all Q outputs and CEU are High. For counting down, the CEOD output is High when all Q outputs are Low and CED is High. To cascade counters, the CEOU and CEOD outputs of each counter are connected directly to the CEU and CED inputs, respectively, of the next stage. The clock, L, and CLR inputs are connected in parallel.
In Xilinx CPLD devices, the maximum clocking frequency of these counter components is unaffected by the number of cascaded stages for all counting and loading functions. The TCU terminal count output is High when all Q outputs are High, regardless of CEU. The TCD output is High when all Q outputs are Low, regardless of CED.
When cascading counters, the final terminal count signals can be produced by AND wiring all the TCU outputs (for the up direction) and all the TCD outputs (for the down direction). The TCU, CEOU, and CEOD outputs are produced by optimizable AND gates within the component, resulting in zero propagation from the CEU and CED inputs and from the Q outputs, provided all connections from each such output remain on-chip. Otherwise, a macrocell buffer delay is introduced.
The counter is initialized to zero (TCU Low and TCD High) when power is applied. For CPLDs, the power-on condition can be simulated by applying a High-level pulse on the PRLD global net.
Inputs | Outputs | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
CLR | L | CEU | CED | C | Dz-D0 | Qz-Q0 | TCU | TCD | CEOU | CEOD |
1 | X | X | X | X | X | 0 | 0 | 1 | 0 | CEOD |
0 | 1 | X | X | Dn | dn | TCU | TCD | CEOU | CEOD | |
0 | 0 | 0 | 0 | X | X | No Chg | No Chg | No Chg | 0 | 0 |
0 | 0 | 1 | 0 | X | Inc | TCU | TCD | CEOU | 0 | |
0 | 0 | 0 | 1 | X | Dec | TCU | TCD | 0 | CEOD | |
0 | 0 | 1 | 1 | X | Inc | TCU | TCD | Invalid | Invalid | |
z = 1 for CB2X1; z = 3 for CB4X1; z = 7 for CB8X1; z = 15 for CB16X1 dn = state of referenced input (Dn) one setup time prior to active clock transition TCU = QzQ(z-1)Q(z-2)...Q0 TCD = !Qz!Q(z-1)!Q(z-2)...!Q0 CEOU = TCUCEU CEOD = TCDCED |